Front Console Panel Display Status and Error Codes For AirCAT

This guide is to help read your console display on your AirCAT!

Speed adjust bar

Below is a picture of the "Speed Adjust Bar". It show between 2 and 20 bars depending on the pressure. If 1 or no bars are showing, you will get a LO error. If the pressure is adjusted too quickly and fills beyond the max capacity, the timer display will read HI.

  • If the timer display shows HI, then please turn the speed adjust to the left until you hear air releasing and the HI reading has disappeared. 

 

  • When diagnosing an issue, set the speed adjust to 10 bars.

AirCat Speed adjust 10bars

The timer LED will show the mode and error codes

Aircat Timer

Modes:

Timer mode: shows a number that counts down before a launch. If no ball is in the launch area, it wont launch and the AirCAT will reset, showing 2 dashes.

If a reset happens add Volleyballs to the machine. Then you can either hit the remote button to restart the timer or turn the "Mode switch" to RESET then back to TIMER.


Remote mode: Shows 2 dashes - If no ball is in the launch area, it won't launch.

Timer Error codes

LO: Shows immediately when turning on the AirCAT, when the speed knob is adjusted all the way to left, or when power is not going to the air compression pumps. It won't launch with a LO reading. Try turning the speed adjust knob to the right to increase pressure. 

a. If the LO reading will not turn off, and you do not air filling in the machine, follow the BATTERY TROUBLESHOOTING GUIDE

b. You may hear a high pitched hissing sound, indicating an air leak. If so, follow the AIR LEAK TROUBLESHOOTING GUIDE


HI: The AirCAT wont launch with a HI reading. Release pressure by turning the speed adjust knob to the left.  If you are unable to get the HI reading to turn off, contact us.

L6/Lb: Low battery indicator. - Charge the battery for 6 hours. If it still shows this indicator, a new battery is needed. More info can be found in the BATTERY TROUBLESHOOTING GUIDE

 

If you were unable to resolve the issue with the above steps please reach out to our Support+ Team. To get connected with them start a service ticket here or you can call the team at 612-412-4410. They will need the Serial number of your machine, the shipping address, and the results of the troubleshooting. With that, they will be able to provide further assistance.